Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Building Services Engineering Research & Technology ; 44(2):113-133, 2023.
Article in English | ProQuest Central | ID: covidwho-2270569

ABSTRACT

To assess risk factors for COVID-19 transmission and address the closure of mass gathering events since March 2020, the UK Government ran the Events Research Programme (ERP), following which it reopened live events in sports, music, and culture in July 2021. We report the rapid post-occupancy evaluation of Indoor Air Quality (IAQ) and associated long-range airborne transmission risk conducted in the Environmental Study of the ERP. Ten large venues around the UK were monitored with CO2 sensors at a high spatial and temporal resolution during 90 events. An IAQ Index based on CO2 concentration was developed, and all monitored spaces were classified in bands from A to G based on their average and maximum CO2 concentrations from all events. High resolution monitoring and the IAQ Index depicted the overall state of ventilation at live events, and allowed identification of issues with ventilation effectiveness and distribution, and of spaces with poor ventilation and the settings in which long-range airborne transmission risk may be increased. In numerous settings, CO2 concentrations were found to follow patterns relating to event management and specific occupancy of spaces around the venues. Good ventilation was observed in 90% of spaces monitored for given occupancies. Practical applications: High-resolution monitoring of indoor CO2 concentrations is necessary to detect the spatial variation of indoor air quality (IAQ) in large mass gathering event venues. The paper summarises COVID-19 ventilation guidance for buildings and defines a methodology for measurement and rapid assessment of IAQ during occupancy at live events that can be implemented by venue managers. Comparisons of the CO2 concentrations measured during the events identified the spaces at high risk of long-range transmission of airborne pathogens. Building operators should be mindful of the ventilation strategies used relative to the total occupancy in different spaces and the occupant's activities.

2.
Build Environ ; 234: 109967, 2023 Apr 15.
Article in English | MEDLINE | ID: covidwho-2270057

ABSTRACT

CO2-based infection risk monitoring is highly recommended during the current COVID-19 pandemic. However, the CO2 monitoring thresholds proposed in the literature are mainly for spaces with fixed occupants. Determining CO2 threshold is challenging in spaces with changing occupancy due to the co-existence of quanta and CO2 remaining from previous occupants. Here, we propose a new calculation framework for deriving safe excess CO2 thresholds (above outdoor level), C t, for various spaces with fixed/changing occupancy and analyze the uncertainty involved. We categorized common indoor spaces into three scenarios based on their occupancy conditions, e.g., fixed or varying infection ratios (infectors/occupants). We proved that the rebreathed fraction-based model can be applied directly for deriving C t in the case of a fixed infection ratio (Scenario 1 and Scenario 2). In the case of varying infection ratios (Scenario 3), C t derivation must follow the general calculation framework due to the existence of initial quanta/excess CO2. Otherwise, C t can be significantly biased (e.g., 260 ppm) when the infection ratio varies greatly. C t can vary significantly based on specific space factors such as occupant number, physical activity, and community prevalence, e.g., 7 ppm for gym and 890 ppm for lecture hall, indicating C t must be determined on a case-by-case basis. An uncertainty of up to 6 orders of magnitude for C t was found for all cases due to uncertainty in emissions of quanta and CO2, thus emphasizing the role of accurate emissions data in determining C t.

3.
Building Services Engineering Research & Technology ; 2022.
Article in English | Web of Science | ID: covidwho-2194836

ABSTRACT

To assess risk factors for COVID-19 transmission and address the closure of mass gathering events since March 2020, the UK Government ran the Events Research Programme (ERP), following which it reopened live events in sports, music, and culture in July 2021. We report the rapid post-occupancy evaluation of Indoor Air Quality (IAQ) and associated long-range airborne transmission risk conducted in the Environmental Study of the ERP. Ten large venues around the UK were monitored with CO2 sensors at a high spatial and temporal resolution during 90 events. An IAQ Index based on CO2 concentration was developed, and all monitored spaces were classified in bands from A to G based on their average and maximum CO2 concentrations from all events. High resolution monitoring and the IAQ Index depicted the overall state of ventilation at live events, and allowed identification of issues with ventilation effectiveness and distribution, and of spaces with poor ventilation and the settings in which long-range airborne transmission risk may be increased. In numerous settings, CO2 concentrations were found to follow patterns relating to event management and specific occupancy of spaces around the venues. Good ventilation was observed in 90% of spaces monitored for given occupancies. Practical applications: High-resolution monitoring of indoor CO2 concentrations is necessary to detect the spatial variation of indoor air quality (IAQ) in large mass gathering event venues. The paper summarises COVID-19 ventilation guidance for buildings and defines a methodology for measurement and rapid assessment of IAQ during occupancy at live events that can be implemented by venue managers. Comparisons of the CO2 concentrations measured during the events identified the spaces at high risk of long-range transmission of airborne pathogens. Building operators should be mindful of the ventilation strategies used relative to the total occupancy in different spaces and the occupant's activities.

4.
Environ Res ; 211: 113038, 2022 08.
Article in English | MEDLINE | ID: covidwho-1906998

ABSTRACT

There are important questions surrounding the potential contribution of outdoor and indoor air quality in the transmission of SARS-CoV-2 and perpetuation of COVID-19 epidemic waves. Environmental health may be a critical component of COVID-19 prevention. The public health community and health agencies should consider the evolving evidence in their recommendations and statements, and work to issue occupational guidelines. Evidence coming from the current epidemiological and experimental research is expected to add knowledge about virus diffusion, COVID-19 severity in most polluted areas, inter-personal distance requirements and need for wearing face masks in indoor or outdoor environments. The COVID-19 pandemic has highlighted the need for maintaining particulate matter concentrations at low levels for multiple health-related reasons, which may also include the spread of SARS-CoV-2. Indoor environments represent even a more crucial challenge to cope with, as it is easier for the SARS-COV2 to spread, remain vital and infect other subjects in closed spaces in the presence of already infected asymptomatic or mildly symptomatic people. The potential merits of preventive measures, such as CO2 monitoring associated with natural or controlled mechanical ventilation and air purification, for schools, indoor public places (restaurants, offices, hotels, museums, theatres/cinemas etc.) and transportations need to be carefully considered. Hospital settings and nursing/retirement homes as well as emergency rooms, infectious diseases divisions and ambulances represent higher risk indoor environments and may require additional monitoring and specific decontamination strategies based on mechanical ventilation or air purification.


Subject(s)
Air Pollution, Indoor , COVID-19 , COVID-19/epidemiology , COVID-19/prevention & control , Humans , Pandemics/prevention & control , Particulate Matter , RNA, Viral , SARS-CoV-2
5.
Atmospheric Environment ; : 119176, 2022.
Article in English | ScienceDirect | ID: covidwho-1850684

ABSTRACT

CO2 monitoring has proven to be an effective and affordable way of controlling air ventilation rates, a paramount task for minimizing airborne contagions in indoor shared spaces. In this work, the CO2 distribution in a naturally-ventilated classroom has been thoroughly characterized, gaining information not only on the effectiveness of diverse ventilation strategies but also on the expected differences between CO2 values when varying the sampling location within the room. The results confirm that an adequate renewal of the air in the room requires the use of cross-ventilation, with openings in different walls. Furthermore, it was found that ventilation is optimized, for a given total opening area, when the openings are distributed as much as possible among different windows. For most of the studied conditions, a global windows opening area of 1.24 m2 with an open door was typically enough to yield CO2 concentrations below 700 ppm. The CO2 readings displayed a noticeable and consistent dependency on the sampling height, with below-average values at 0.75 m, the highest concentrations at 1.5 m, and levels close to the average when sampling at a height of 2.2 m. For a given height, the influence of the sampling location within the room was weaker, and more dependent on the specific ventilation strategy applied. However, the tests consistently showed CO2 records significantly lower for sensors installed on the walls. Besides a detailed spatial and temporal characterization of the ventilation process under different ventilation strategies, these results are thought to provide useful and novel information for a judicious placement of CO2 monitoring systems.

6.
HardwareX ; 11: e00261, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1616684

ABSTRACT

In the face of a global pandemic, such as that caused by the SARS-CoV-2 virus, the prevention of new infections is essential to stop the spread and ultimately return to normality. In addition to wearing masks and maintaining safe distances, regular ventilation in enclosed spaces where several people are gathered has proven to be an effective protective measure as advised by the World Health Organization. Additionally, as has been shown in a recent study of other airborne viruses, there is a strong correlation between the CO2level and aerosol content in a confined space under the assumption humans are the only CO2source. This can be exploited by means of a low-cost infrared CO2sensor to indirectly monitor the aerosol content and to provide targeted ventilation if predefined thresholds are exceeded. The distributed CO2monitoring network presented in this paper extends that idea and provides an inexpensive, comprehensive and modular monitoring network based on readily available components and 3D printing. By using a long-range communication link (LoRa) to centrally collect the real-time CO2concentration in a multitude of rooms, this network is particularly suitable for larger building complexes such as kindergartens, schools and universities without requiring partial or even full WLAN coverage.

SELECTION OF CITATIONS
SEARCH DETAIL